20
English
Problem
The coffee is not hot
enough.
 
Coffee does not come
out or coffee comes out
slowly.
 
 
Cause
The grinder is set to a too
coarse setting.
The temperature is set too low.
A cold cup reduces the
temperature of the drink.
Adding milk reduces the
temperature of the drink.
The AquaClean water filter was
not prepared properly for
installation.
The AquaClean water filter is
clogged.
The grinder is set to a too fine
setting.
The brew group is dirty.
The coffee dispensing spout is
dirty.
The pre-ground coffee
compartment is clogged
The machine circuit is blocked
by limescale.
Solution
Set the grinder to a finer (lower) setting.
Brew 2 to 3 drinks to be able to taste
the full difference.
Set the temperature to the maximum
setting (Fig. 42).
Preheat the cups by rinsing them with
hot water.
Regardless of whether you add hot or
cold milk, adding milk always reduces
the temperature of the coffee. Preheat
the cups by rinsing them with hot water.
Remove the AquaClean filter and
dispense some hot water. If this works,
the AquaClean filter was not installed
properly. Reinstall and activate the
AquaClean filter and follow all steps in
chapter 'AquaClean water filter'.
After a long period of non-use, you
need to prepare the AquaClean water
filter for use again and dispense 2-3
cups of hot water.
Replace the AquaClean water filter
every 3 months. A filter that is older
than 3 months can become clogged.
Set the grinder to a coarser (higher)
setting. Note that this will impact the
coffee taste.
Remove the brew group and rinse it
under the tap (see 'Cleaning the brew
group under the tap').
Clean the coffee dispensing spout and
its holes with a pipe cleaner or needle.
Switch off the machine and remove the
brew group. Open the lid of the pre-
ground coffee compartment and insert
the spoon handle into it. Move the
handle up and down until the clogged
ground coffee falls down (Fig. 28).
Descale the machine with Philips
descaler (see 'Descaling procedure').
Always descale when the machine
prompts you.