eng
4. Faults
4.1. Fault: The desired test pressure is not reached.
Cause:
● Suction fi lter (6) is blocked.
● Return valve (14) does not close
● O-ring on pump piston damaged.
● Hand pressure testing pump sucks in air.
● Installed system leaking.
● Shut-off valve (F) not closed.
● Hand pressure testing pump defective.
4.2. Fault: Test pressure is not held.
Cause:
● Shut-off valve (E) and/or (F) not closed.
● Installed system leaking.
● Hand pressure testing pump defective.
4.3. Fault: Pump lever (4) rises.
Cause:
● Ball of the pump on pressure side does not close.
● Hand pressure testing pump defective.
5. Disposal
The hand pressure testing pump may not be thrown into the domestic waste
at the end of use. It must be disposed of properly by law.
6. Manufacturer's Warranty
The warranty period shall be 12 months from delivery of the new product to the
fi rst user. The date of delivery shall be documented by the submission of the
original purchase documents, which must include the date of purchase and the
designation of the product. All functional defects occurring within the warranty
period, which are clearly the consequence of defects in production or materials,
will be remedied free of charge. The remedy of defects shall not extend or
renew the warranty period for the product. Damage attributable to natural wear
and tear, incorrect treatment or misuse, failure to observe the operational
instructions, unsuitable operating materials, excessive demand, use for unau-
thorized purposes, interventions by the customer or a third party or other
reasons, for which REMS is not responsible, shall be excluded from the warranty
Services under the warranty may only be provided by customer service stations
authorized for this purpose by REMS. Complaints will only be accepted if the
product is returned to a customer service station authorized by REMS without
prior interference in an unassembled condition. Replaced products and parts
shall become the property of REMS.
The user shall be responsible for the cost of shipping and returning the product.
The legal rights of the user, in particular the right to make claims against the
seller under the warranty terms, shall not be affected. This manufacturer's
warranty only applies for new products which are purchased in the European
Union, in Norway or in Switzerland.
This warranty is subject to German law with the exclusion of the United Nations
Convention on Contracts for the International Sales of Goods (CISG).
7. Spare parts lists
For spare parts lists, see www.rems.de → Downloads → Parts lists.
6
Remedy:
● Clean suction fi lter, change if necessary.
● Clean return valve and seal seat, change return valve if necessary.
● Change O-ring.
● Check water/liquid level in the tank (3), fi ll up if necessary.
● Seal installed system.
● Close shut-off valve.
● Have the hand pressure testing pump checked/repaired by an authorised
REMS customer service workshop.
Remedy:
● Close shut-off valve.
● Seal installed system.
● Close shut-off valve (E). Have the hand pressure testing pump checked/
repaired by an authorised REMS customer service workshop.
Remedy:
● Clean ball and ball seat, change ball if necessary.
● Have the hand pressure testing pump checked/repaired by an authorised
REMS customer service workshop.
eng