SENSOR(S) RESYNCHRONIZATION
Press the [ SENSOR / WI-FI ] key once for the console to enter sensor Synchronization mode
(channel number blinking), and the console will re-register all the sensors that have already been
paired to it before.
REMOVE WIRELESS SENSOR
User may manually delete any sensor from the console.
1. Press the [ CH / SET ] key until the console shows the display of the selected sensor.
2. Press and hold [ RESET ] key for 10 seconds, until its readings are reset " -- , -
shown.

3.3 RECOMMENDATION FOR BEST WIRELESS COMMUNICATION

Effective wireless communication is susceptible to noise interference in the environment, and
distance and barriers between the sensor transmitter and the display console.
1. Electromagnetic interference (EMI) – these may be generated by machinery, appliances,
lighting, dimmers and computers, etc. So please keep your display console 1 or 2 meters
away from these items.
2. Radio-frequency interference (RFI) – if you have other devices operating on 868 / 915 / 917
MHz, you might experience communication intermittent. Please re-located your transmitter or
display console to avoid signal intermittent problem.
3. Distance. Path loss occurs naturally with distance. This device is rated to 100m (300 feet) by
line of sight (in interference free environment and without barriers). However, typically you will
get 30m (100 feet) maximum in real life installation, which includes passing through barriers.
4. Barriers. Radio signal are blocked by metal barriers such as aluminum cladding. Please align
the sensor array and display console to get them in clear line of sight through window if you
have metal cladding.
The table below show a typical level of reduction in signal strength each time the signal passed
through these building materials
MATERIALS
Glass (untreated)
Wood
Plasterboard / drywall
Brick
Foil insulation
Concrete wall
Aluminum siding
Metal wall
Remarks: RF signal reduction for reference.
SIGNAL STRENGTH REDUCTION
10 ~ 20%
10 ~ 30%
20 ~ 40%
30 ~ 50%
60 ~ 70%
80 ~ 90%
100%
100%
11