Configure DIAG

Fig. 64 Speedway Target Configuration
Fig. 65 Interface Settings

Speedway

Run the "DIAG Suprasetter" program and select "Speedway" on the "Interface" tab in "Options /
Properties".
66
Prerequisite: The CTP User Interface must not be
running.
Launch "DIAGNOSE Suprasetter_A52_A74" from
the Start menu.
The "Speedway Target Configuration" window, in
which you must set "Main Target" to "active",
appears on top of the large diagnosis window.
Use the "Select" button to open "C:\Program-
Files(x86)\Heidelberg\CTP\Diagnose Supraset-
ter_A75\DIAG Suprasetter_A75\Diag Supraset-
ter.tdb".
In the "Interface Settings" dialog, select "Supraset-
ter_A52_74" as the target.
Select "Ethernet" as the type.
In "Ethernet", type in 172.16.0.2 as the IP address
and 59350 as the IP port.
Confirm with OK.