1. About this document

Please read carefully and keep in a safe place.
– Under copyright. Reproduction either in whole or
in part only with our consent.
– Subject to change in the interest of technical
progress.
Symbols
!
Hazard warning!
Reference to other information in the
...
document.

2. General safety precautions

Disconnect the power supply before
!
attempting any work on the unit.
• During installation, the electric power cable being
connected must not be live. Therefore, switch off
the power first and use a voltage tester to make
sure the wiring is off-circuit.
• Installing the sensor-switched light involves work
on the mains supply voltage. This work must
therefore be carried out professionally in accord-
ance with national wiring regulations and electrical
operating conditions. (e.g.: DE: VDE 0100,
AT: ÖVE / ÖNORM E8001-1, CH: SEV 1000)
• Only use genuine replacement parts.
• Repairs may only be made by specialist workshops.
3. DL Vario Quattro PRO S
Proper use
– The Vario Quattro is a sensor-switched light for
indoor and outdoor ceiling mounting.
The sensor-switched light is equipped with four
pyro sensors that detect the invisible heat emitted
by moving objects (people, animals, etc.). The heat
detected in this way is converted electronically
into a signal that switches the light ON. Heat is not
detected through obstacles, such as walls or panes
of glass, and will therefore not activate the light.
Note:
The light's shade is susceptible to scratching. The
light must not be installed near radiant heaters.
Package contents (Fig. 3�1)
– Sensor-switched light
– Spacer
– Retaining strap
Product dimensions (Fig. 3�2)
Product components (Fig. 3�3)
A Light
B Reach adjustment
C Connecting terminal
D Twilight setting
E Time setting
F Basic light level
G Relay ON/OFF
H Ceiling mount
Detection zone (Fig. 3�4)
Luminous intensity distribution (Fig� 3�5)
4� Electrical connection
Wiring diagram (Fig� 4�1)
a) Single light
b) Connection with other loads
c) Second light interconnected
The mains supply lead is a 3-core cable (max. lead
diameter 19 mm):
L
= phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors
using a voltage tester; then disconnect from the
power supply again. Connect the phase conductor
(L) and neutral conductor (N) to the terminal block.
Insulate protective-earth conductor (PE) and place
it next to terminal block.
Important:
Mixing up the connections will produce a short
circuit in the product or your fuse box. In this case,
you must identify the individual conductors once
again and reconnect them. A mains power switch
for turning the unit ON and OFF may of course be
installed in the mains supply lead.
The light source of this luminaire cannot be
replaced. If the light source needs to be replaced
(e.g. at the end of its service life), the complete
luminaire must be replaced.