4. Electrical connection

Wiring diagram (Fig. 4.1)
The supply lead is a three-core cable:
L
= phase conductor (usually black,
brown or grey)
N
= neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors
using a voltage tester; then disconnect from the
power supply again. Connect phase (L) and neutral
conductor (N) to the connecting terminal; optionally,
protective-earth conductor (PE) can be connected
to terminal (E).
Important:
incorrectly wired connections will produce a short
circuit later on in the product or fuse box. In this
case, you must identify the individual conductors
once again and reconnect them. A mains switch for
switching the product ON and OFF may, of course,
be installed in the mains supply lead. The light source
of this luminaire cannot be replaced.
If the light source needs to be replaced (e.g. at the
end of its service life), the complete luminaire must
be replaced.
5. Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• When installing the LED luminaire, make sure the
installation site is not subject to vibration.
• Select an appropriate mounting location, taking
the reach and motion detection into consideration.
Mounting procedure
• Switch OFF power supply (Fig. 4.1)
• Undo screws (Fig. 5.1)
• Press catch and pull luminaire off the wall mount
(Fig. 5.2)
• Undo retaining strap and terminal and remove
luminaire (Fig. 5.3)
• Mark drill holes (Fig. 5.4)
• Drill holes and insert wall plugs (Fig. 5.5)
• Pierce sealing plug for power supply lead (Fig. 5.6)
• Concealed mounting (Fig. 5.7)
• Surface mounting (Fig. 5.8)
• Attach retaining strap and terminal to the wall
mount (Fig. 5.9)
• Connect conductors (Fig. 5.10)
• Remove retaining strap on lamp side and store in
wall mount (Fig. 5.11)
• Install luminaire enclosure on wall mount (Fig. 5.12)
• Tighten screws (Fig. 5.13)
• Switch ON power supply (Fig. 5.13)
• Make settings ➜ "6. Function"
6. Function
Factory settings L 710 S
Time setting:
Twilight setting:
Basic light level:
L 710 N factory settings
Twilight setting:
Basic light level:
ON/OFF in the morning: ON
Time setting L 710 S (Fig. 6.1 H)
The light's stay ON time can be set to any period
from approx. 5 seconds to a maximum of 15 min-
utes. Any movement detected before this time
elapses will restart the timer.
Twilight setting (Fig. 6.1 G)
The chosen response threshold can be infinitely
varied from approx. 2 to 2000 lux.
– Control dial set to
(depending on ambient brightness)
– Control dial set to
(approx. 2 lux)
Basic light level (Fig. 6.1 F)
Standard programme
– Soft light start / no basic light level
What is soft light start?
The sensor-switched light features a soft light start
function. This means that when turned ON, the light
is not switched directly to maximum output but con-
stantly builds up brightness to 100% within a short
period of time. Brightness is also gradually reduced
when the light is switched OFF.
User-friendly economy programme
– Soft light start + basic light level until the middle
of the night
– Basic light level ON from twilight setting selected
until the middle of the night
– 15 –
5 seconds
daytime operation
OFF
daytime operation
OFF
= daylight mode
= twilight mode