Herunterladen Inhalt Inhalt Diese Seite drucken

Diagnostics And Fault Elimination; Error Types - Lenze Smart Motor m300 Bedienungsanleitung

Drehstrommotoren
Vorschau ausblenden Andere Handbücher für Smart Motor m300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Diagnostics and fault elimination

Diagnostics and fault elimination
Fault messages are stored in the logbook of the Lenze Smart Motor.
How to read out the fault messages:
1. Disconnect Lenze Smart motor from the mains.
2. Load parameter set onto the smartphone or the EASY Starter. Under "History", the last 4 messages are
stored in the logbook.
a) Up to firmware version 02.00.00.00: Identical errors that occur successively are displayed as one entry.
b) From firmware version 02.01.00.00: Each error is displayed as an entry.
How to reset errors:
1. Eliminate the cause of malfunction.
2. The error is reset by mains switching.
The drive can be started again.
You can reset the fault without mains switching:
Select the input speed 0 rpm via the digital inputs.
Then select the desired speed again.
If the cause of malfunction is no longer active, the drive will restart.

Error types

Fault
Type
Meaning
F
Fault
W
Warning
76
Drive behaviour
The digital output changes to LOW = not ready for operation.
The fault is entered in the history buffer.
• Lenze Smart Motor without brake: The motor is switched off and coasts down.
• Lenze Smart motor with brake: The motor is switched off; the brake is applied.
The fault is entered in the history buffer.
The Lenze Smart motor continues running.

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis