Herunterladen Inhalt Inhalt Diese Seite drucken

Axis Q6032-C Installationsanleitung Seite 17

Vorschau ausblenden Andere Handbücher für Q6032-C:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 45
AXIS Q6032-C/Q6034-C/Q6035-C Installation Guide
7. Make sure the clamp is in place and tighten the screws.
The shield and the clamp surface shall be in full contact with each other so that the multi-
connector cable is grounded.
8. Connect the network cables to the external network connectors (RJ-45, SFP) as required.
Ground screw
Multi-connector
cable
I/O connector
(external)
9. If applicable, connect an I/O device to the external I/O connector.
10. Connect the power cable (DC input) to the power connector (DC input).
11. Attach the ground wire to the ground screw.
Power cable (DC input)
Power connector
(DC input)
Network connector
SFP (external) (2x)
Network connector
RJ-45 (external) (2x)