C.2

Designing the system

Ensure that the system has been planned in accordance with the codes of practice and the applicable planning stand-
ards.
Observe the planning information for the units that are to be integrated.
Observe the same basic hydraulic diagrams, see section "Basic hydraulic diagrams".
Note the following points in the event of dimensioning that is tailored according to requirements:
VPS buffer cylinder
Domestic hot water demand (adapted to the VPM W domestic hot water station)
Heat load
Type of boiler (running time, bridging time)
VPM W domestic hot water station
Domestic hot water demand, depends on:
Number of people
Type of application
Simultaneity
Buffer cylinder volume
Heating expansion vessel
System volume (incl. buffer cylinder)
System height or expansion vessel pre-charge pressure
Water trap
Heat generator
Technologies:
Oil-fired floor-standing boilers/oil-fired condensing boilers
Gas-fired floor-standing boilers/gas-fired condensing boilers/gas-fired boilers
Pellet boilers
Heat pumps (water, brine, air)

Circulation pump

Actuation
Pressure level
Volume flow
Heating circuits
Any number of heating circuits is possible (depends on the control)
Heating circuit types:
Static heating surfaces
Underfloor heating surfaces
Max. flow temperature 40 °C
Heat interface units
Regulated heating circuits
Maximum total output of the heating circuits:
3
VPS 800: 15 m
/h
3
VPS 1000: 15 m
/h
3
VPS 1500: 30 m
/h
3
VPS 2000: 30 m
/h
0020314387_00 allSTOR plus Installation and maintenance instructions