Block lock Activation master
8 Setting the jumpers at the master
Jumper B1
Jumper B2
Jumper B3
9 Technical specifications
VdS approval
numbers
Housing
EN
Jumper connects B1.b and B1.c: Activation master
beeps after activation release (acknowledgement
of activation request by activation master)
Jumper connects B1.b and B1.a: Activation master
beeps when burglar alarm system pulls pin 29 to
ground (VdS-compliant: Acknowledgement of
activation by burglar alarm system)
If jumper B2 is inserted, the range of the internal
antenna is maximised. The range of the optional
external antenna remains unchanged.
You limit the range of the external antenna with an
aluminium sleeve. In this case, set the jumper.
Using the external antenna without an aluminium
sleeve is not VdS-compliant. The manual provides
more information.
Do not plug in jumper B3.
Activation unit - G101160 - Class C
Deactivation unit - G101161 - Class C
Block lock function - G102014 - Class C
Dimensions
Colour
Material
8. Setting the jumpers at the
84.5 mm × 84.5 mm ×
26 mm
White
S-B or ABS
master
29 / 112