Herunterladen Inhalt Inhalt Diese Seite drucken

Riello Family KIS Bedienungs- Und Installationsanleitung Seite 10

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 173
FAMILY
4
CONTROL PANEL (REC10)
The REC10 remote control has the function of a machine interface, displaying the system
settings and providing access to the parameters.
The middle of the main screen displays the temperature of the domestic hot water delivery
(if there is a storage cylinder with probe - optional) unless there is a heat request in heating
mode, in this case the delivery temperature of the boiler is displayed.
The value expressed in bar refers to the system's water pressure.
The top of the screen shows the information regarding the current date and time, as well as
the outdoor temperature, if available.
On the left and right sides are displayed the icons indicating the status of the system, their
meaning is the following:
REC10
Keys area
This icon indicates that the OFF operating status mode has been set. Each ignition request is ignored except for the anti-freeze function. The pump anti-lock, 3-way valve and anti-
freeze function remain active.
This icon indicates that WINTER mode has been selected (HEATING function enabled). If a heating request from the main zone is in progress, the icon will be flashing.
This icon indicates that the circuit for domestic hot water production is enabled. When a domestic hot water request is in progress, the icon flashes. The P at the top of the domestic
hot water icon indicates that the boiler pre-heating function is enabled; the P when flashing indicates that a pre-heating request is in progress.
When the "central heating programming timing" function is enabled this icon indicates that the system heating (main zone) is in AUTOMATIC mode (the management of the heating
requests follows what has been set with the timer).
If the heating function is not enabled during the current time frame, the icon will be crossed out.
When the "central heating programming timing" function is enabled this icon indicates that the system heating (main zone) is in MANUAL mode (the management of the heating
requests does not follow what has been set with the programming timing, but it is always active).
This icon indicates that the system (main zone) has been set to off (not active).
OFF
This icon indicates that the system is detecting the presence of a flame.
This icon indicates the presence of an anomaly, and is always flashing.
The display of the REC10 control panel is equipped with the new "Color Bar" that rapidly
informs the user about the boiler operation.
The operating states and the alarms are grouped by 4 colours:
- GREEN: normal operation, the system is serving domestic hot water/heating requests or
else automatic functions like, for example, anti-legionella, antifreeze, flue cleaning, etc..
Scrolling text describes the function active in that moment
- YELLOW: presence of faults that could be resolved by the user that allow the product to
operate even partially. An error triangle on the display gives access to details about the
fault like, for example, "call for service", domestic hot water probe fault, etc...
- RED: presence of lockout faults that require the intervention of the Technical Assistance
Centre. An error triangle on the display gives access to details about the fault like, for
example, "stop for service", lockout, etc...
- GREY: system is ready to meet any requests or functions, no fault detected.
If several conditions are present at the same time, the signal on the main screen
corresponds to the highest priority, in the following ascending order: Grey, Green, Yellow
and Red.
Pressing the "UP" and "DOWN" keys it is possible to select from among the following
options:
• PLANT: a scrolling message on the display can indicate the temperature of the domestic
hot water probe rather than the flow sensor of the boiler
10
Boiler control panel
ENTER = confirm
BACK= Return to the previous page / cancel selection
Return to the main screen (press > 2 sec.)
+ =
Allows you to choose between the options: PLANT, STATE, SET, INFO, MENU and to navigate through the sub-menus
scrolling upwards
- =
Allows you to choose between the options: PLANT, STATE, SET, INFO, MENU and to navigate through the sub-menus scroll-
ing downwards
Info
CONFIRM
FRI
18/05/2013
MENU
CANCEL button
GO BACK
• STATE (when the PLANT screen is selected): to set the status of the boiler (OFF,
SUMMER or WINTER) and, when managed by the room thermostat, the operating mode
of the main area in heating mode (ON or OFF) if the programming timing is disabled,
AUTO according to hourly programming, MANUAL or OFF if programming timing is
enabled)
• SET: to establish the heating or hot water setpoint value or for activating pre-heating
• INFO: to display the value of the system variables
• MENU: to access the system's configuration menus
The configuration MENU is organised with a multi-level tree structure. With the "ENTER"
key you can access the selected sub-menu, with the "UP" and "DOWN" keys it is possible
to navigate the sub-menus, while with the "BACK" key you return to the previous level.
An access level has been fixed for each sub-menu: USER level always available;
TECHNICAL level password protected.
Below is a summary of the MENU tree structure of the REC10.
b
Some of the information might not be available on the REC10 depending on the
access level, the status of the machine or the system configuration.
PLANT
12:17
bar
STATE
1.3
42
°C
INFO
SET
HOT WATER TEMPERATURE
REC10
UP key
DOWN key

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis