Herunterladen Inhalt Inhalt Diese Seite drucken

Spare Parts - Gemü Q40 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Q40:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Lay tube lines professionally!
▶ Lay tube lines professionally and do not bend them below
the minimum bending radius, see manufacturer's inform-
ation.
Do not kink or twist the tube lines.
Exceptional maintenance work!
▶ Damage to the GEMÜ product.
Any maintenance work and repairs not described in these
operating instructions must not be performed without
consulting the manufacturer first.
The operator must carry out regular visual examination of the
GEMÜ products depending on the operating conditions and
the potential danger in order to prevent leakage and damage.
The product also must be disassembled and checked for
wear in the corresponding intervals.
1. Have servicing and maintenance work performed by
trained personnel.
2. Wear appropriate protective gear as specified in plant op-
erator's guidelines.
3. Shut off plant or plant component.
4. Secure plant or plant component against recommission-
ing.
5. Depressurize the plant or plant component.
6. Actuate GEMÜ products which are always in the same po-
sition four times a year.

10.1 Spare parts

Spare parts on request.
10.2 Removing the tube
Risk of crushing!
▶ While the tube holder is open, the actu-
ator can move. Severe injury due to
crushing or shearing of the fingers.
Ensure that the actuator remains in the
open position during tube replace-
ment.
Do not reach into the tube crushing
area.
1. Move the actuator A to the open position.
WARNING! Pneumatic actuator with control function 1:
Risk of crushing due to the compressor shutting down.
Ensure that the actuator remains in the open position dur-
ing tube replacement. Do not reach into the tube crushing
area.
www.gemu-group.com
NOTICE
NOTICE
CAUTION
2. Turn the locking ring b by 90° in the direction of the arrow.
ð The word "unlocked" can be read on the tube holder.
3. Open the tube holder 1.
4. Remove the tube.
10.3 Disassembling the tube holder
1. Remove the tube (see "Removing the tube", page 29).
2. Loosen the fixing screw c using an Allen key.
3. Remove the tube holder 1.
29 / 36
10 Inspection and maintenance
b
1
1
c
GEMÜ Q40

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gemü q30Q30

Inhaltsverzeichnis