Test logical inputs and outputs
+
3 sec.
In out
SEriAl
tStout
TEStin
During the I / O test execution phase the weight control is disabled, use this procedure only to check the
hardware.
Test outputs
Test inputs
Set password
AnALoG
oP2ion
CoStAn
Test outputs
Test inputs
The status of the outputs is indicated on the display. 0 = output deactivat-
ed, 1 = output activated. Output 1 corresponds to the 1st digit on the left.
During this procedure the LEDs correspond to the status of the outputs.
(see page 61 of the manual).
To set the digits use the keys as in the numerical settings.
The display indicates the status of the inputs.0 = input disabled, 1 = input
activated. Input 1 corresponds to the 1st digit on the left.
Activate and deactivate the inputs (see page 49 of the manual) to check
the corresponding status on the display