Herunterladen Inhalt Inhalt Diese Seite drucken

Storage, Transport, Disposal And Recycling; Limited Warranty - Permobil ROHO Hybrid Elite Cushion Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
Cleaning and Disinfecting, continued
Machine Wash and Disinfect the Cushion
IMPORTANT: Machine washing can cause wear and damage, including cuts and tears to the cushion and the detachment of required product
information. Washing and disinfecting the cushion by hand and air drying is strongly recommended.
Warnings:
- DO NOT machine wash or machine dry the contoured foam base or the foam insert. DO NOT machine dry the cushion insert.
- DO NOT allow water or cleaning solution to enter the cushion. Make sure the inflation valve(s) are closed. Hybrid Elite SR: Make sure the Smart
Check is detached from the cushion. Water in a cushion with Sensor Ready (SR) technology can result in damage to the Smart Check and cause a
false reading when using Smart Check.
- High water temperature may cause cushion discoloration and label detachment.
- DO NOT expose cushions to temperatures above 70°C (158°F), which may damage cushion components.
- For machine washing or disinfecting, make sure the washing machine capacity is sufficient. A washing machine that isn't large enough may not
remove all soil or contaminants from a cushion.
- Using a damaged cushion will reduce or eliminate the benefits of the cushion and increase risk to skin and other soft tissue.
Prepare the Cushion for Machine Cleaning:
1) Remove the cover and close the inflation valve(s). Make sure the Smart Check is detached from the cushion (Hybrid Elite SR). Examine the cushion
for damage, and patch any holes (refer to Repair Kit instructions provided with the product).
2) Remove stains or odors as needed: Place the cushion in warm water and a disinfectant cleaning agent. Gently scrub, using a soft plastic bristle
brush, and rinse with clean water.
3) Deflate the cushion: Open the inflation valve and roll up the cushion, starting at the corner opposite the valve. After you have removed as much air
as possible, close the inflation valve.
4) Inspect for any sharp edges in the washing machine that may damage the cushion.
Machine Wash the Cushion:
Place the cushion in a laundry bag and then into the washing machine. When folding the cushion, make sure the air cells face outward.
Use warm water (85º - 105ºF / 30º - 40ºC) and laundry detergent or machine- and cushion-safe cleaner/biocide, placed in the detergent dispenser.
Gentle cycle: Use a machine setting that does not include a high-speed spin cycle.
Machine Disinfect the Cushion: Follow the machine washing instructions and use hot water 60°C (140°F). Use biocide (refer to the
manufacturer instructions). Bleach with care: Only use a dilution of 1 part household liquid bleach per 9 parts water. Rinse with clean water.
Caution: Rinse thoroughly. Detergent residue may cause air cells to stick together.
Drying the Cushion: Remove the cushion from the laundry bag and air dry. For faster drying, use a hand-held hair dryer, hold no closer than
6 in. (15 cm) from the cushion, and use a sweeping motion.
Warning: Overheating the neoprene rubber can cause permanent product damage.
Care Symbols
Hand wash.
Line dry in the shade.
Machine wash hot, normal, at
60C
the temperature shown.

Storage, Transport, Disposal and Recycling

Storage and Transport: Clean and disinfect the product before storing. Open the inflation valve(s). Deflate the product. Store the product in a container that
protects the product from moisture, contaminants and damage. After storing, follow instructions to prepare the product for use. After transport, inspect the
product to ensure it was not damaged (see Troubleshooting).
Disposal: The components of the products in this manual are associated with no known environmental hazards when properly used and when disposed
of in accordance with all local/regional regulations. At the end of its useful life, treat as healthcare waste and dispose of according to local healthcare-waste
guidelines. Incinerate with other healthcare waste. Incineration must be performed by a qualified, licensed waste management facility.
Recycling: Contact a local recycling agency to determine recycling options for the product.

Limited Warranty

Limited Warranty Term: 24 months from the date the product was originally purchased. The warranty does not apply to punctures, tears, burns, or misuse. See
also the instructions provided with the cover and the Limited Warranty supplement provided with your product, or contact Customer Support.
ROHO Hybrid Elite Cushion Operation Manual
Bleach (1 part bleach: 9 parts water).
1:9
Use a handheld dryer.
Wipe with a damp cloth.
8
40C
Machine wash, warm, gentle.
Hand wash cold.
Dry flat in the shade.
40C
60C
+
1:9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis