Assembly

Assembling the switch box

Straighten out the sensor cable so it is not twisted and
screw into the four-pole connection on the left by hand.
Straighten out the Bodyguard cable so it is not twisted
and screw into the three-pole connection on the right by
hand.
Line up the cables and push the switch box into the
switch box holder until it locks into place. Be sure that
none of the cables is twisted.
Bodyguard, prepare function test
On the BG 4 pressure reducer:
Close the plastic/metal elbow connection (1) with the R
33 790 sealing plug which is included with the R 33 777
testing kit so that it is gastight.
NOTICE
Connection (2) will not be closed. The air flows off through
the constant dosage valve.
On the Tramix pressure reducer:
Close the two plastic/metal plug elbow connectors (3)
with the R 33 790 sealing plug which is included with the
R 33 777 testing kit, so that it is gastight.
NOTICE
Connection (2) is not closed. The air flows off through the
constant dosage device.