safety
This appliance may only be fitted by a registered gas fitter.
Check the connections for leaks using soapy water before
using the appliance.
gas connection RC 3/8"
(ISO 7/1-RC 3/8)
A 3/8" to 1/2" reducing adapter (ISO 228-1-G 1/2A) is supplied
for those countries where it is required
The gas connection must comply with national and local
regulations.
These stipulate, among other things, that:
– only approved materials may be used;
– plastic hoses may not be used behind built-in ovens or
underneath hobs.
electrical connection
230 V AC – 50 Hz – 0,6 W
The house mains to which the appliance is connected should
comply with national and local regulations.
Connect the appliance to a wall socket which has been
installed in accordance with current regulations.
The wall socket and plug should remain accessible at all times.
Caution: The appliance must be earthed.
GB 14
.
building in dimensions
750
526
min.
50
490
space to be left free arround the appliance
A hob generates heat. Leave a sufficient distance between
the appliance and non heat-resistant materials.
min. 600 mm
min. 650 mm
min. 450 mm
min. 100 mm
The gas hob may only be built in next to one vertical wall.
installation instructions
general
46
560
min. 100 mm
GB 15