6. COMMISSIONING
6.1 Electrical Connections
To improve immunity to the possible noise radiated towards other appliances it is recommended to use a separate electrical duct to supply the
product.
The line voltage may change when the electropump is started. The line voltage may undergo variations depending on other
devices connected to it and on the quality of the line.
Make sure that the mains voltage is the same as that on the motor data plate.
Strictly observe the wiring diagrams below:
-
L-N-Earth, single-phase version
U-V-W-Earth, three-phase version
-
The appliance must be connected to a main switch that cuts off all the power supply poles. When the switch is in off position, the distance
separating each contact must respect the indications in table 2.
The cable gland, supplied with the terminal box, binds the outer diameter of the cable sheath in a range between 7 and 13mm. The mammoth
terminal block can accommodate cables with a lead cross-section up to 2.5mm2 (AWG14 for USA versions).
6.2 Configuration of the Integrated Inverter
The system is configured by the manufacturer to satisfy the majority of installation cases, that is:
•
operation at constant pressure;
•
Set-Point (desired value of constant pressure):
•
Reduction of pressure to restart:
•
Anti-cycling function:
However, all these parameters can be set by the user (see the chapter Settable parameters)
The system does not work if the utility is at a height higher than the equivalent in metres of water column of the Pstart (consider 1 bar = 10 m.
water column): for the default configuration, if the utility is at a height of at least 27m the system does not start.
6.3 Priming
For the first start-up, follow the steps below:
Minimum distance between the contacts of the power switch
Minimum distance [mm]
ENGLISH
Figure 10
>3
Table 2
SP = 3.0 bar
RP = 0.3 bar
Disabled
45