V500 io
3.1 Standard installation
230 V AC
230 V AC
• With wall socket:
• With DIN rail power supply:
Distance between the
DIN rail power supply
and the monitor (L)
< 25 m
< 35 m
< 50 m
Note: We recommend that, if possible, the video entry phone cables should not be routed through the same sheath as the power
supply cables.
The cables are not supplied.
Copyright © 2019 SOMFY ACTIVITES SA. All rights reserved.
3 - INSTALLATION
Optional
230 V AC
2-wire
230 V AC
Cable to be used
2-wire 0.5 mm²
min.
2-wire 0.75 mm²
min.
2-wire 1 mm²
Distance between the door
station and the monitor
Less than 100 m
Between 100 and 150 m
2-wire
2 x 0,75 mm² : 150 m max.
2 x 0,5 mm² : 100 m max.
2 x 0,75 mm² : 150 m max.
2 x 0,5 mm² : 100 m max.
Cable to be used
2-wire 0.5 mm² min.
2-wire 1 mm² max.
2-wire 0.75 mm² min.
2-wire 1 mm² max.
8 m
max.
230 V AC
L
230 V AC
EN
EN
8 m
max.
230 V AC
L
230 V AC
6