BTL7-V50T-M _ _ _ _ -P-SA447-C003/_ _ _ _
Magnetostrictive linear position sensor – Set
4
Initialization of the system (continued)
Establishing connection to controller
1. Use C
plC to configure the IP address of the
OnneCt tO
controller and the number of the databases.
2. Use C
ip
and C
heCk
addreSS
whether the connection is functional.
Fig. 4-3:
Establishing connection to controller
3. If all settings are correct, save the connection settings
with S
.
ave
www.balluff.com
to test
heCk databaSeS
Performing the initialization
1. After successful connection to the PLC, initialize the
system via i
/r
.
nitS
eSet
Fig. 4-4:
Initialize system
⇒ After initialization, the system provides position
values.
2. Traverse the entire measuring range so that the
complete magnet signature can be recorded and
stored.
Locking the magnet database
Once the complete measuring range has been traversed, it
is recommended to lock the magnet database to prevent
changes. This is possible via the Parameters dialog.
► Lock the magnet database by activating the checkbox
for M
anual blOCk Of MagnetS databaSe
Fig. 4-5:
Locking the magnet database
.
english
19