Problem
Hand switch does not
work.
Hand switch/massage
chair does not react when
several devices are con-
nected.
8. Technical Data
Supply
Dimensions
Weight
Maximum load capacity
9. Disposal
Empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling
points or electronics retailers. You are legally required to dispose of the batteries.
The codes below are printed on batteries containing harmful substances:
Pb = Battery contains lead,
Cd = Battery contains cadmium,
Hg = Battery contains mercury.
For environmental reasons, do not dispose of the device in the household waste at the end of its service
life. Dispose of the device at a suitable local collection or recycling point.
Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment).
If you have any questions, please contact the local authorities responsible for waste disposal.
10.
Warranty and service
Beurer GmbH, Söflinger Straße 218, 89077 Ulm, Germany (hereinafter referred to as "Beurer") provides a warran-
ty for this product, subject to the requirements below and to the extent described as follows.
The warranty conditions below shall not affect the seller's statutory warranty obligations which ensue
from the sales agreement with the buyer.
The warranty shall apply without prejudice to any mandatory statutory provisions on liability.
Beurer guarantees the perfect functionality and completeness of this product.
The worldwide warranty period is 2 years, commencing from the purchase of the new, unused product from the
seller.
The warranty only applies to products purchased by the buyer as a consumer and used exclusively for personal
purposes in the context of domestic use.
German law shall apply.
During the warranty period, should this product prove to be incomplete or defective in functionality in accordance
with the following provisions, Beurer shall carry out a repair or a replacement delivery free of charge, in ac-
cordance with these warranty conditions.
If the buyer wishes to make a warranty claim, they should approach their local retailer in the first instance:
see the attached "International Service" list of service addresses.
Cause
Hand switch is not configured to
the massage chair.
Hand switch signal is not uni-
quely assigned to one device
220-240 V~, 50/60 Hz, 120 W
162 x 73 x 76 cm
ca. 50,5 kg
150 kg
Solution
To configure the hand switch, point it towards
the bottom half of the back rest. It should be no
more than 40 cm away.
Press the On/Off button on the hand switch until
the LED above the relax massage programme
lights up. After approximately 3-4 seconds, LED
4 starts to flash and then switches off. The hand
switch is now configured and ready for use.
Maintain a minimum distance of approx. 15 met-
res between the massage chairs.