Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Maintenance / Cleaning - Delabie TEMPOFLUX Bedienungsanleitung

Selbstschluss-druckspüler für wc für hinterwandmontage
Vorschau ausblenden Andere Handbücher für TEMPOFLUX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 9

OPERATION

• Press the push-button to operate.
• Automatic timed shut-off after ~7 seconds.
INSTALLATION
• When installing in-line valves, always respect the direction of the water flow.
• Activate the valve several times to stabilise timing.
REMEMBER
• Our mixers must be installed by professional installers in accordance with current regulations and
recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer (see calculation
table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency
of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the mixer to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
MAINTENANCE
Foreign bodies in the system may cause the valve to malfunction:
• Time flow too long or continuous flushing: Clean the interior of the delay case with a dry cloth,
and the calibrated groove with a non-metallic point.
• Dripping or a constant trickle: Clean the seat washer in the valve body, and check/clean the seat joint
and replace the cartridge if damaged.
• Leak under the push button: Replace the cartridge.
• Water discharge from the vacuum breaker: Check flush tube is not fully inserted up to the WC pan
and check flush tube radius is at 50mm.
• No flush: Dynamic pressure is too weak, pipe work sizing is incorrect, or flush tube curve is 90°.
Note: do not grease inside the mechanism.
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the mixer several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
For the UK market only: Tel. 01491 821 821 - email: technical@delabie.co.uk
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: sav@delabie.fr
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tempoflux 2

Inhaltsverzeichnis