17 Machine configuration
In this menu, it is possible to recall soft-
i
ware versions (revision) and make set-
tings to the machine configuration.
 Call up the secondary parameters by pressing
button 29.
 Call-up the machine configuration menu by
pressing button 29 for 2 sec.
You are now in the Machine configuration
menu. The parameter code and the parameter
value are alternatingly shown.
 Set the desired menu point by rotating the con-
trol knob 19.
Code
rEL
Master version number
rEP
Process version number
SoI
rEd Display version number
rEI
Primary version number
StP
Start peak
IGO
HFP HF power
IFS
Special 4-stroke
Sbt
Auto standby time
Fuse option (230V)
FuO
Fuse option (115V)
This parameter sets the mains power fuse used.
The max. selectable current is also limited at this point. See "Fuse options" on
Page 37.
FuS
Various main parameters are available, depending on the mains connection.
Fur
Fuse power reduction
When the "Fuse power reduction (Fur) is activated, the welding current will
be dynamically reduced as required according to the fuse option set (FuO) to
prevent the main fuse from tripping. This is indicated by the On/Off button 28
flashing at a higher rate.
PLL Powermaster LED lock
On: The "Mode" button at the i-LTG/i-LTW series torch is locked. Pressing the
Tor
Mode button for 2 sec. unlocks this button for 15 sec. The "Mode" button will im-
mediately be locked when the start/stop button is pressed during these 15 sec.
- 36 -
Parameter
909.4039.9-03
Machine configuration
 Confirm the menu point by pressing operating
button 19.
9 The parameter value flashes when the param-
eter is settable.
 Change the value of a parameter by turning
control knob 19.
 Store the change by pressing control knob 19.
A description of the menu structure is provided
in the following table.
 Press button 29 to terminate a change without
storing or to exit a menu level.
Standard
Setting range
value
100 %
100 %
OFF
30 min
Off, 5...30 min
16A
10, 10F, 13, 13F,16, 16F
25A
20, 20F, 25, 25F
OFF
OFF
1 - 200 %
40 - 100 %
OFF - On
OFF - On
OFF - On
Mode
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
04.19