Adjust power limiting as required
NOtE
The door opener is preset to stage 3 by the supplier.
If required (e. g. if the power level is too low) you
can subsequently adjust the power limiting setting.
1. P ress „ P" for
approx. 5 seconds.
4. P ress „+" or press „–"
to select the stage.
5. P ress „P", in order
to store the setting.
After a resetting of the power level, it is absolutely necessary to repeat the reference run for power limit-
ing and to conclude the programming again.
Risk of injury if reference run is not undertaken for purposes of power measurement. Also there is a risk of
injury during the reference run process, as the drive develops a high degree of force.
If the power level is too low, the door move-
ment will be impaired, particularly if the
mechanical structure of the door is not well
balanced.
2. Press „+".
(if necessary press several
times) until„4" is displayed.
Low
Factory setting
6. I MPORtANt
Repeat reference run
for power limiting
(refer to page 60).
3. P ress „P", the display
shows „ 7" (stage 3).
Power level
7. C onclude program-
ming (refer to page 66,
method 1).
EN
High
61