18
Messages
18.1
Informative messages
After the message has been output, the
i
i
machine will only function to a limited ex-
tent; the error must be corrected as quickly
as possible.
Code
Note
H01
Undervoltage
H03
Fans
H04
PFC
H05
EEProm checksum error
H06
EEProm write/read error
H10
Torch protection
Tab. 10: Informative messages
- 56 -
Cause
Mains voltage too low
Fan fault
PFC faulty
Communication with EEProm faulty
Communication with EEProm faulty
Torch doesn't send ID although torch
protection is activated
909.2679.9-01
Possible remedy
Check mains voltage
Inform Service
Inform Service
Switch machine off and on again, execute
master reset
Switch machine off and on again, execute
master reset
Adjust torch-ID
Messages
03.19