Herunterladen Inhalt Inhalt Diese Seite drucken

Messages; Informative Messages - LORCH Control Pro T-Serie Bedienungshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
18

Messages

18.1

Informative messages

After the message has been output, the
i
i
machine will only function to a limited ex-
tent; the error must be corrected as quickly
as possible.
Code
Note
H01
Undervoltage
H03
Fans
H04
PFC
H05
EEProm checksum error
H06
EEProm write/read error
H10
Torch protection
Tab. 10: Informative messages
- 56 -
Cause
Mains voltage too low
Fan fault
PFC faulty
Communication with EEProm faulty
Communication with EEProm faulty
Torch doesn't send ID although torch
protection is activated
909.2679.9-01
Possible remedy
Check mains voltage
Inform Service
Inform Service
Switch machine off and on again, execute
master reset
Switch machine off and on again, execute
master reset
Adjust torch-ID