Technical specifications
12
Technical specifications
Device short description:
Supply voltage:
Current consumption:
Power consumption in standby:
Degree of protection:
Ambient temperature:
Degree of pollution:
Measurement category:
Radio frequency:
Receiver category:
Typ. open area RF range:
Duty cycle:
Max. switching capacity:
Load type:
Life expectancy relay/
switching cycle:
Relay:
Switch type:
Operating mode:
Withstand voltage:
Protection class:
Method of operation:
Dimensions (W x H x D):
Weight:
40
HM-ES-PMSw1-PI-DN-R5
230 V/50 Hz
10 A max.
-10 to +35 °C
868.3 MHz
SRD category 2
< 1 % per h
ohmic load
40000 (10 A, ohmic load)
Shutter contact, 1-pole, μ contact
independently mounted switch
59 x 122 x 40 mm (not incl. mains plug)
Power
Current
< 0.6 W
IP20
Voltage
2
CAT II
Frequency
300 m
*Frequency range: 2 Hz to 2 kHz
2300 W
Subject to technical changes.
S1
2500 V
I
Type 1 B
.
167 g
Measuring range
0 to 2300 W
0 to 10 A
200 to 255 V
48.72 to 51.27 Hz
Instructions for disposal
Do not dispose of the device with regular domestic waste.
Electronic equipment must be disposed of at local collection
points for waste electronic equipment in compliance with the
Waste Electrical and Electronic Equipment Directive
Information about conformity
The CE Marking is simply an official symbol relating to the free
movement of a product; it does not warrant a product's charac-
teristics.
For technical support, please contact your retailer.
Technical specifications
Resolution
Accuracy
0.01 W
1 %
± 0.03 W*
1 mA
1 %
± 1 mA*
0.1 V
0.5 %
± 0.1 V
0.01 Hz
0.1 %
± 0.01 Hz
41