10.3
Connecting 230 V
A
NOTICE!
• Connect a relay or a switch to the vehicle's electrical system so that
the generator is not damaged when the external mains is connected.
• Ensure that the electrical system is set up as follows:
– TN network:
The neutral conductor must be linked to the PE conductor on the
terminal via a jumper with a minimum diameter of 2.5 mm². To
protect against automatic shutdown, make sure that a safety
switch (FI switch, 30 mA) and an in all-pole overcurrent protec-
tion (e.g. circuit breaker, 13 A) are installed.
– IT network:
Ensure that an insulation monitor and an in all-pole overcurrent
protection (e.g. circuit breaker, 13 A) are installed.
• Connect the generator so that it takes priority over the power supply.
➤ Guide the 230 V connection cable through the cable passage in the housing and
connect it to the 230 V terminals (fig. g 7, page 11).
➤ Connect the earth cable to the earth connection (fig. g 6, page 11).
10.4

Connecting the battery charger

➤ Connect the positive terminal of the battery with the 12 V connection of the bat-
tery charger using a cable with a cross-section of 2.5 mm² (fig. g 5, page 11).
➤ If the battery to be charged is not also the starter battery, connect the negative
terminal of the battery to be charged to the generator's earth cable (fig. h 1,
page 11).
10.5
Connecting the starter battery
A
NOTICE!
The starter battery must have 12 V and a capacity of at least 60 Ah.
➤ Connect the positive terminal of the battery to the positive battery terminal con-
nection using a cable with a cross-section of 10 mm² for a length of < 6 m or
16 mm² for a length of > 6 m (fig. g 8, page 11).
➤ Fit a 100 A fuse in the positive cable near the positive terminal of the starter bat-
tery to protect the generator's electrical system.