Connecting the electrical power to the generator
10.3
Connecting 230 V
NOTICE!
A
Connect a relay or a switch to the vehicle's electrical system
(see "Accessories" on page 37) so that the generator is not
damaged when the power supply is switched on.
Ensure that the electrical system is set up as follows:
– TNS network:
The neutral conductor must be linked to the PE conductor on
the terminal via a jumper with a minimum diameter of
2.5 mm
that a safety switch (FI switch, 30 mA) and an in all-pole
overcurrent protection (e.g. circuit breaker, 13 A) are in-
stalled.
– IT network:
Ensure that an insulation monitor and an in all-pole overcur-
rent protection (e.g. circuit breaker, 13 A) are installed.
Connect the generator so that it takes priority over the power
supply.
➤ Guide the 230 V connection cable through the cable passage in the hous-
ing and connect it to the 230 V terminals (for TEC29: fig. e 7, page 9, for
TEC29LPG: fig. f 6, page 9).
➤ Connect the earth cable to the earth connection on (fig. e 6, page 9, for
TEC29LPG: fig. f 7, page 9).
10.4
Connecting the battery charger
➤ Connect the positive terminal of the battery with the 12 V connection of
the battery charger using a cable with a cross-section of 2.5 mm² (for
TEC29: fig. e 5, page 9, for TEC29LPG: fig. f 8, page 9).
➤ If the battery to be charged is not also the starter battery, connect the neg-
ative terminal of the battery to be charged to the generator's earth cable
(fig. g 1, page 10).
46
2
. To protect against automatic shutdown, make sure
TEC29, TEC29LPG
EN