AUTO SENSE mode:

Display measurement result at AC only with RMS value or DC value, it
depends on whichever is greater.
AC mode: AC only with RMS value.
DC mode: DC value.
AC+DC mode: AC+DC RMS value.
Note:
• Select " AC", " DC" or " AC+DC" indicator then press the navigator
key to enter the AC/DC/AC+DC mode.
• Select " AC"," DC" or " AC+DC" indicator then press the navigator
key for more than 2 seconds to return to the AUTO SENSE mode.

PEAK HOLD

(AC mode only)
1. In ACV mode, select "
" indicator on the display to enter PEAK
HOLD mode. To exit PEAK HOLD mode, press the navigator key for
more than 2 seconds.
"ENTER"
>2SEC
2. In AC A mode, select "
" indicator then press the navigator key for
more than 2 seconds to enter PEAK HOLD mode. To exit PEAK HOLD
mode, just press the navigator key for more than 2 seconds to return
to the "
" indicator.
>2SEC
"ENTER"