Operation
Comfortable SLEEP
Before going to bed, you can simply press the SLEEP
button and unit will operate in SLEEP mode and bring you
a sound sleep.
Operation Mode
1. In COOL, DRY mode
1 hour after SLEEP mode starts,
temp. will become 1°C higher
than temp. setting. After another
1 hour, temp. rises by 1°C again.
The unit will run for another 6
hours then stop.
Temp. under sleep mode is
higher than temp. setting so that
room temperature won't be too
low for sleep.after SLEEP mode
SLEEP
operation starts
1 hr
1 hr
Temp. setting
In COOL, DRY mode
2. In HEAT mode
1 hour after SLEEP mode starts, temp will become
2°C lower than temp. setting. After another 1 hour,
temp decrease by 2°C again. After another 3 hours,
temp. rises by 1°C. The unit will run for another 3
hours and then stop.
7
8
Press SLEEP
button.
SLEEP
operation stops
Approx. 6hrs
Rises 1
C
º
Rises 1
C
º
Unit stop
Temp. under SLEEP mode is lower than temp. setting
so that the room temperature won't be too high for
sleep.
Temp. setting
1 hr
Decreases 2
1 hr
3 hrs
SLEEP
operation starts
In HEAT mode
3. In SMART mode
The unit operates in corresponding sleep mode, which
adapted to the automatically selected operation mode.
4. When SLEEP mode is set to 8 hours the
time can not be adjusted. When TIMER
function is set, the SLEEP mode can't be
set up. After the SLEEP mode is set up, if user
resets TIMER function, the SLEEP mode will be
cancelled; the machine will be in the state of timing-
on, if the two modes are set up at the same time, either
automatically, and the other mode will be cancelled.
Power Failure Resume Function
not start running unless 3 minutes have passed . When
the power resumes after power failure, the unit will run
automatically, and 3 minutes later the compressor starts
running.
Note to the power failure resume:
enter function after hearing four sounds. And press the
this function after hearing two sounds.
Unit stop
C
º
Decreases 2
C
º
3 hrs
Rises 1
C
º
SLEEP
operation stops