Herunterladen Inhalt Inhalt Diese Seite drucken

Toshiba MMU-AP0071MH Installations-Handbuch Seite 29

Raumeinheit
Vorschau ausblenden Andere Handbücher für MMU-AP0071MH:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 60
Main
Outdoor 7-segment display
remote
controller
display
P01
P03
P03
P04
P04
P05
P05
P07
P07
P10
P10 Detected indoor address
P12
P13
P13
P15
P15
P17
P17
P19
P19 Detected outdoor unit number
P20
P20
P22
P22
P26
P26
P29
P29
P31
P31
Error detected by TCC-LINK central control device
Central
Outdoor 7-segment display
control
device
indication
C05
C06
C12
P30
Terminology
TCC-LINK : TOSHIBA Carriea Cominication Link.
Downloaded from
www.Manualslib.com
Check code
AI-NET central
control display
Auxiliary code
11
1E
01: Comp. 1 side
21
02: Comp. 2 side
01: Phase-missing detection
AF
02: Phase error
01: Comp. 1 side
IC
02: Comp. 2 side
Ob
11
47
01: TS condition
AE
02: TD condition
bb
O8
22
0
: IGBT short
: Fan motor position
1
detective circuit error
3
: Fan motor trouble
1A
: TH sensor temp. error
C
(Heat sink overheat)
D
: TH sensor error
E
: Vdc output error
01: Comp. 1 side
14
02: Comp. 2 side
01: Comp. 1 side
16
02: Comp. 2 side
47
b7
97
99
Check code
AI-NET central
control display
Auxiliary code
Differs according to error contents of unit with occurrence of alarm
manuals search engine
Wireless remote controller
Sensor block display
of receiving unit
Timer Ready Flash
Operation
¤ ¤
l
ALT Indoor fan motor error
¤
¤
l
ALT Discharge temp. TD1 error
¤
¤
l
ALT High-pressure SW system operation
¤
¤
l
ALT Phase-missing detection /Phase error
¤
¤
l
ALT Heat sink overheat error
l
¤ ¤
ALT Indoor overflow error
¤ ¤
l
ALT Indoor fan motor error
¤ ¤
l
ALT Outdoor liquid back detection error
¤
¤
l
ALT Gas leak detection
¤
l
¤
ALT Discharge temp. TD2 error
¤
l
¤
ALT 4-way valve inverse error
¤
¤
l
ALT High-pressure protective operation
¤
¤
l
ALT Outdoor fan IPDU error
¤
l
¤
ALT G-TR short protection error
¤
¤
l
ALT Comp position detective circuit system error
¤
¤
l
ALT Other indoor unit error (Group terminal unit error)
By alarm device
ALT Error in indoor group
AI-NET communication system error
Duplicated network adapters
Wireless remote controller
Sensor block display
of receiving unit
Operation
Timer Ready Flash
Sending error in TCC-LINK central control
device
Receiving error in TCC-LINK central control
device
Batch alarm of general-purpose equipment
control interface
Group control branching unit error
(L20 is displayed.)
Duplicated central control addresses
26
Check code name
Check code name
Judging device
TCC-LINK
TCC-LINK
General-purpose equipment
TCC-LINK
Judging device
Indoor
I/F
IPDU
I/F
IPDU, I/F
Indoor
Indoor
I/F
I/F
I/F
I/F
I/F
IPDU
IPDU
IPDU
Indoor
AI-NET
AI-NET
AI-NET
I/F