Electrical connection

DANGER
Danger through incorrectly dimensioned connection
cables.
The system is intended exclusively for operation
with the connection pipes provided (or equivalent).
In case of doubt, contact the manufacturer/supplier.
Lay the connection cable securely (e.g. conduit pipe) from
the system tank to the control unit. Ensure that there is
adequate cable length for the maintenance of the electri-
cal components.
Attach ferrules (length 8 mm) to the cable ends.
Unscrew and remove housing cover.
74 / 144
Pumping station / Installation and operating manual
Feed connection cable through suitable cable pass-
through.
Fasten connection cable to the terminal strips in accor-
dance with connection diagram.
To do so, use a suitable screwdriver to hold down the
respective cable clamp against the spring pressure until
the cable end has been inserted.
Fasten strain relief for all connection cables - tightening
torque 0.5 Nm.
Fit battery connector onto the battery.
Route the battery cable such that the LEDs are not cov-
ered or trapped.
Fit the housing cover and fasten in place - screw tighten-
ing torque 1.2 Nm.