Herunterladen Inhalt Inhalt Diese Seite drucken

Deleting Data; Delete Data; Expert Mode; Maintenance - Bosch ACS 611 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für ACS 611:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
i
The software A/C Data Manager (optional
accessory) can be used to view and manage the
data on a PC.
11.9.4

Deleting data

1. Press <MENU>.
2. Select "REPORT MANAGEMENT" with o u and
confirm with E.
3. Select DELETE DATA with o u and confirm with E.

DELETE DATA?

1 - YES
2 - NO
4. Delete all protocols with <1>.
i
The protocols cannot be deleted individually.

11.10 Expert mode

i
When expert mode is activated, supporting
messages for individual action steps are not
displayed on the screen.
1. Call up the start screen.
2. Press <3> and <Flush> simultaneously and release.
 The message
ENTER CODE 0000
2222
and confirm with E .
3. Enter
4. Select "EXPERT MODE"" with o u and confirm
with E.
5. Select activate or deactivate with o u and confirm
withE .
"
Expert mode is activated or deactivated.
i
Return with <Stop>.
Robert Bosch GmbH

12. Maintenance

!
Work on electrical equipment is only to be
performed by persons with sufficient knowledge
and experience of electrical systems!
12.1
!
Do not use abrasive cleaning agents and coarse
workshop cloths!
The housing and the LCD are only to be cleaned
using a soft cloth and neutral cleaning agents.
12.2
Description
Combo filter
Vacuum pump oil
Roll of paper for printer
Service hose (HP) 2,5 m
Service hose (HP) 5 m
Service hose (LP) 2,5 m
Service hose (LP) 5 m
Quick-release coupling (HP)
is displayed.
Quick-release coupling (LP)
Used oil bottle
Fresh oil bottle
UV dye bottle
Adapter set 2,5 m - 5 m
Adapter for connection to an external
refrigerant cylinder 1/4" SAE
Adapter for connection to an external
refrigerant cylinder
W21.8-14 x 1/4" FL (EU Standard)
12.3
Description
Calibration of fresh and used
oil scales
Vacuum pump oil replacement
and system leak test
Replacement of combo filter
!
Never perform any maintenance work which is not
expressly recommended in this Section.
!
Contact customer service if components have to be
replaced other than in the course of maintenance
work.
Maintenance | ACS 611 | 57 |

Cleaning

Spare and wearing parts

Maintenance interval

Period
Once a year or on change of
fresh oil type
see display (10 h)
see display (150 kg)
1 689 989 600
en
Order number
SP00100001
SP00100086
SP00100087
SP00100029
SP00100035
SP00100030
SP00100036
SP00100083
SP00100082
SP00100060
SP00100059
SP00100061
SP00100075
SP00100019
SP00100080
|
2020-12-01

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis