LASER EMISSION DATA
As measured under IEC measurement conditions for classification.
Laser Classification
Red Laser Medium
Green Laser Medium
Blue Laser Medium
Beam Diameter
Pulse Data
Divergence (each
Divergence (total light)
Specifications
Mains Input ......................................................................................... AC100-240V, 50/60Hz
Fuse ................................................................................. 250V 2A Slow Blow (20mm Glass)
Laser power .............................. 2 x 80mW-R-638nm +50mW-G-532nm +150mW-B-450nm
Consumption ................................................................................................................ 100W
Music Control ...................................................................................... Internal microphone
Laser Safety Standard .................................................................................. EN60825-1 2014
Condition Temperature ............................................................................................ 10~40°C
DMX Connections ............................................................................ 3 pins XLR Male/Female
DMX Channels ...................................................................................................... 8 channels
Measurement ......................................................................................... 335 x 200 x 125mm
Weight ......................................................................................................................... 1.5 Kg
Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid
vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure
and able to support a weight of 10 times of the unit's weight. Also always use a safety cable that can hold 12 times
the weight of the unit when installing the fixture.
CONTROLS & FUNCTIONS
When the unit is powered on, the LED monitor on rear panel shows the current operating standalone mode or DMX
address of DMX mode. The LED control panel allows setting and changing the operating mode of the laser very easily.
After every reset or save, the new mode information will be shown on the LED monitor at next power on.
Mode: Set the operating mode of laser.
Confirmation: Confirms all settings or changes of LED control panel.
UP/DOWN: Changes the operating mode, parameter or DMX address.
©Copyright Lotronic 2018
Class 3B
LD 638nm, typical
DPSS Nd:YVO4, 532nm
LD 445nm, typical
<5mm at aperture
All pulses < 4Hz (>0.25sec)
<2 mrad
<90 degrees
LZR360RGB-FX
3