Temperature
Range
-40 to 0 °C
0 to +100 °C
+100 to +1000 °C
>1000 to +1300 °C
-40 to +32 °F
+32 to +212 °F
+212 to +1832 °C
>1832 to +2372 °F
Overload protection: 600 V, Sensor input: Type K
Non-contact AC voltage detection (NCV)
Range
≥220 V
Diode test
Test voltage
Approx. 3.0 V/DC
Overload protection: 600 V; Test voltage: 2 mA typ.
Acoustic continuity tester
Measurement range
600 Ω
≤10 Ω continuous tone; ≥100 Ω no tone
Overload protection: 600 V
Test voltage approx. 1 V
Test current 0.7 mA
Never exceed the maximum permitted input values. Do not touch any circuits or circuit compo-
nents if the circuit has voltages higher than 33 V AC RMS or 70 V DC. Danger of death!
Resolution
1 °C
1 °F
Frequency range
50 – 60 Hz
Resolution
0.001 V
Resolution
0.1 Ω
Accuracy
±(6.0% + 5)
±(1.5% + 4)
±(1.5% + 4)
Not specified
±(6.0% + 9)
±(1.5% + 5)
±(2.5% + 5)
Not specified
Indication
EF = No voltage detection
-
- -
- - -
- - - -
Signal strength not specified
Beep, not specified
Detection range approx.: ≤ 15 mm - 50 mm
75