E 1
Absence of sensitivity calibration.
Perform the sensitivity calibration procedure.
E 2
Error condition during sensitivity calibration.
Repeat sensitivity calibration paying attention to the first spin, which must be
performed with the wheel as in the successive spins.
Take particular care NOT to knock the machine during calibration.
E 3 I/E 2/3 Error condition at the end of sensitivity calibration. Repeat the calibration, if the
message persists perform the following checks:
Correct sensitivity calibration procedure;
Correct fastening and position of the calibration weight;
Mechanical and geometric condition of the calibration weight;
Geometry of the wheel used.
E 4
a) Error condition on ultrasonic sensor calibration. Calibrate the ultrasonic sensor.
b) ultrasonic sensor not present. Visualisation of this error can be disabled by
performing the following procedure:
- Select the icon "Width measuring sensor calibration"
E 6
Error condition when executing optimisation programme.
Repeat the procedure from the beginning.
E 12
Ultrasonic width sensor not present, or faulty. Visualisation of this error can be
disabled by performing the following procedure:
- Select the "Ultrasonic width sensor calibration" icon
and press ENTER.
E 27
Excessive braking time. If the problem persists, contact the technical support
centre.
E 28
Encoder counting error. If the error occurs frequently, call in the technical support
centre.
E 30
Wheel spin device failure. Switch off the machine and call in the technical sup-
port centre.
E 32
The wheel balancer has been jolted during the reading phase. Repeat the spin.
E F0
Error in reading the 0 notch.
CCC CCC Unbalance values greater than 999 grams.
CHECK FOR CORRECT FUNCTIONING OF
BALANCING ACCESSORIES
Checking balancing accessories allows the operator to make sure that wear has not altered
the mechanical specifications of flanges, cones, etc. beyond the specified limits.
A perfectly balanced wheel, which has been disassembled and reassembled in a different
position, should not show an unbalance value greater than 10 grams.
When a higher unbalance is found, check all the accessories carefully and replace the
Operator's Manual MT 3650 Up