- press
It is possible to activate or deactivate the laser when present on the machine.
After the list of the setting programmes is displayed:
- Select the LASER activation/deactivation icon
- Two icons will appear on the display that represent the possible LASER modes, as shown
below:
LASER OFF.
LASER ON. In this configuration, the laser turns on in the following cases:
- for the manual application of all adhesive weights.
IMPORTANT:
If the operator selected an EASY ALU 1 or ALE2P (precise) balancing programme and
there is a weight holder, the laser will not be activated as the weight is applied using the
holder itself.
- in the Hidden Weight programme, the selection of the two new positions behind the
spokes is done in the 6 o'clock position using the laser line.
- Using the Enter button
if it is in the following configuration:
- press
Calibrate when detecting that the setting condition is out-of-tolerance or when the machine
so requires as the E 1 message is displayed.
Calibrate as follows:
1.
select the sensitivity calibration icon
2.
fit a wheel of average dimensions (diameter no less than 14"), with preferably only
a small unbalance, on the wheel balancer;
3.
perform a spin;
4.
At the end of the spin, fix the calibration weight supplied with the machine on the
swinging unit bell as indicated in figure 26.
120
to confirm the selection made and exit the function.
LASER activation/deactivation
, select the desired mode. The selected icon is enabled
to confirm the selection made and exit the function.
Sensitivity Calibration
in the configuration program menu
Operator's Manual MT 3650 Up