BIP AD2-T017-01-EB _ _ -506
Inductive Positioning System
We confirm conformity with
the applicable EU Directives
with the CE marking.
Notes to the user
Validity
This guide describes the construction, function, and setup
options for the BIP inductive positioning system. It applies
to types BIP AD2-T017-01-EB _ _ -506.
The guide is intended for qualified technical personnel.
Read this guide before installing and operating the BIP.
Always observe the warnings in these instructions and the
measures described to avoid hazards.
Scope of delivery
–
BIP
–
User's guide
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
Safety
Intended use
The BIP inductive positioning system, together with a
machine controller (e.g. PLC), comprises a positioning
system. It is intended to be installed into a machine or
system and used in the industrial sector. Flawless function
in accordance with the specifications in the technical data
is ensured only when using original Balluff accessories.
Use of any other components will void the warranty.
Non-approved use
The BIP may not be used in applications where personal
safety depends on proper function of the devices (not
designed in accordance with EU Machinery Directive).
Opening the BIP or non-approved use are not permitted
and will result in the loss of warranty and liability claims
against the manufacturer.
General safety notes
Installation, startup, and maintenance may only be
performed by trained specialists with basic electrical
knowledge. Qualified personnel are those who can
recognize possible hazards and institute the appropriate
safety measures due to their professional training,
knowledge, and experience as well as their understanding
of the relevant regulations pertaining to the work to be
done.
Repairs may only be performed by the manufacturer or an
authorized representative.
Do not attempt to make changes to the device or to
modify it in any way.
1
english
Safety (continued)
The operator is responsible for ensuring that local safety
regulations are observed.
In particular, the operator must take steps to ensure that a
defect in the BIP will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the BIP, it should
be taken out of service and secured against unauthorized
use.
Construction and function
Dimensions
Start
4.1
25
35
LED
Function
The BIP detects the position of the target and outputs it as
a voltage signal.
Installation and connection
Installation instructions
In order to prevent interference with the measurement
signal, a metal-free area of approximately 5 mm should be
maintained around the entire active area of the BIP (see
figure). If the BIP detects not only the target, but also
another metal piece, invalid measurement signals will
result.
To obtain a measurement signal with high resolution,
suitable cable routing in the machine and filter measures
for system power supply must be ensured.
Ø ≤ 3.5
15.1