Operating Instructions
QJ 600-E
Pos : 26 /99 g erätes pez. M odul e/PG2 Vakuum-Verleges ysteme/52400033 QJ 600 e/War tung kompl _QJ 600e @ 3\mod_1258722946975_2.doc x @ 29609 @ 12222 @ 1
7 Maintenance and care
7.1
General Hints
The device may be installed and maintained only by qualified personnel such as mechanics and electricians.
Always disconnect the electric power before starting any maintenance work.
The fans must not be opened during the guarantee period as this will entail loss of guarantee
cover.
After any repair or maintenance work, check the safety devices as described in the section "Safety".
To ensure the correct function, safety and service life of the device the following points must be executed
in the maintenance interval.
Used only original spare parts, otherwise the warranty expires.
All operations may only be made in unpressurised, electro less and closed state of the device!
7.2 Maintenance Plan
Inspect the safety devices:
- Vacuum gauge OK?
Electrical equipment OK? Cable glands tight?
All connections (hose clamps, etc.) tight?
Instruction plate, rating plate and load plate still mounted on
the device?
Operating instructions available?
Operating personnel familiar with operating instructions?
Inspect load-carrying part (such as suspension) for
deformation, wear and other damage.
Clean and inspect suction pads. Must be free of cracks, lip
must be smooth, etc. Replace if necessary.
Clean the air filter
Is the inspection sticker up to date?
General condition of the device.
Leak test
23 / 25
Maintenance and care
Daily
Interval
Weekly Monthly Every 6
X
X
X
X
Every 12
months
months
X
X
X
X
X
x
X
X
X
X
GB