Herunterladen Inhalt Inhalt Diese Seite drucken

Lighting The Fire; Adding Fuel / Heating At Nominal Thermal Output - HASE Merida Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Merida:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
CAUTION!
To prevent adverse effects on health, nobody
should stay in the room(s) during this process
unless absolutely necessary. Make sure the
room is well-ventilated and open the windows
and outside doors. If needed, use a fan for
faster air circulation.
If the maximum temperature is not reached during the fi rst
heating operation, you may notice an odour for a short period
of time the next time the stove is used as well.
7.

Lighting the Fire

The fi ring up phase should be as short as possible, since higher
emissions can occur during this phase.
The slider settings described in Table 1 (see fi gure on the
right) are recommendations that were determined under
conformance testing conditions, in compliance with the
relevant standard. Depending on the weather conditions and
the draught capability of your chimney, accordingly adjust the
slider positions for your Merida to the local conditions.
NOTE!
The Merida may only be operated when the fi re
box door is closed; the fi re box door may
only be opened to add fuel.
WARNING!
Never use spirits, petrol, or other fl ammable
fl uids to light the stove.
36
Downloaded from
www.Manualslib.com
Procedure
Completely open primary
and secondary air.
Open fi re grate.
Pile up any remaining ash
and unburned Charcoal
into the centre of the
combustion chamber.
Place 2-3 small logs into
the middle of the fi re box;
stack approx. 0.5 kg of dry
wood chips on top.
Light the ignition material
at several places.
Tab. 1
Fig. 7
manuals search engine
Lighting the Fire
Position of Control
Elements
Pull primary and secondary air
slider all the way out. (fi g. 7)
Pull out fi re grate slider.
Open fi re box door.
Close fi re box door.
(I)
(II)
8.

Adding Fuel / Heating at Nominal Thermal Output

More fuel should be added to the fi re when the fl ames from
the previous burning off phase have just gone out.
Adding Fuel / Heating at Nominal Output
Procedure
Control Elements
Adjust primary and
Close primary air slider
secondary air.
(I), set secondary air slider
(II) to position 3. (fi g. 8)
Close fi re grate.
Push in fi re grate slider.
Add two logs weighing approx.
Open fi re box door.
0,8 kg in total. Place logs with
one end to the front of fi re box.
Only add a single layer of fuel.
Close fi re box door.
Tab. 2
(I)
(II)
Fig. 8
Position of

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis