Herunterladen Inhalt Inhalt Diese Seite drucken

Commissioning, Operation - WIKA FLM-CA Betriebsanleitung

Magnetostriktiv-füllstandstransmitter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5. Commissioning, operation

5. Commissioning, operation
DANGER!
Risk of injury due to improper use
EN
Work on containers involves the danger of intoxication and suffocation.
5.1 Mounting
Screw-in body
During mounting, ensure that the guide tube is not bent and that the float is not
subjected to shock loads.
The installation of the level transmitter in areas with strong external magnetic fields is
not permitted, since this will impede the correct measured value determination.
The level transmitter can also be installed in the vessel from below. If the vessel is also
pressurised, then the maximum length of the level transmitter is 2 m.
10
No work is allowed to be carried out unless by taking suitable personal
protective measures (e.g. breathing apparatus, protective clothing etc.).
Work on the instrument must only be carried out by trained skilled
personnel.
Probe head
Screw-in
body
Guide tube
Float
Adjusting
collar
Operating instructions magnetostrictive level transmitter, models FLM-CA, FLM-CM
Flange
Probe head
Neck tube
Flange
Guide tube
Float
Adjusting
collar
Mounting on bypass