Metal plate drilling:Apply low speed when start drilling; steady pressure is applied to the tool, please increase to full power. Please use
cutting lubricating oil. But when drilling holes on iron and copper materials, dry drilling should be used. When drilling large diameter
holes, drill holes should be pre bored for smooth progress.
warning:
This excessive pressure can only damage the drill bit, reduce the machine performance and shorten the service life of the
machine
The holes drilled through will produce great force on the drill bit. So when the drill began to drill through the workpiece, and
be careful to hold the machine. When the workpiece to be processed is very small, it must be clamped with a vise or other
clamping tools. Do not drill holes in materials that may contain nails or other objects that may be jammed or damaged
turn around screw:
The machine should apply tool clamp when it is used as a screwdriver. The screwdriver head should be matched with the screw head.
When the machine rotates clockwise, the screws can be tightened and the screws can be removed when rotating counterclockwise. The
rotation direction can be changed only when the machine is completely stopped, otherwise it will damage the machine.
Note:
The rotation direction can be changed only when the machine is completely stopped, otherwise it will damage the machine

Maintenance:

Under normal usage, this product needs minimal maintenance. To maintain satisfactory results, proper maintenance and regular
cleaning should be carried out.
Note:
Please turn off the power and pull the plug before any maintenance
1 ) Regular use soft brush to clean ventilation grooves
2)Regular use dry cloth to clean the fuselage shell
3)Replace carbon brushes: regular inspection and replacement of carbon brushes. When the carbon brush wears out 5
millimeters, it needs to be replaced. To keep carbon brush clean and make it slip freely in the brush grip. Two carbon brushes
should be replaced at the same time
4)Carbon brush replacement: use the screwdriver to open the case and remove the worn carbon brush, install a new carbon
brush in the brush holder, and close the case

Environmental protection:

Disposal of waste:
In order to respond to environmental protection, the damaged machine, accessories and packaging materials must be sorted
in detail so as to facilitate recycling