Hardware
10.10 Special accessories
10.10.1 Pressure transducer
•
Pressure Range: 0-300 psig
•
Operating Temperature Range: -40 to
105°C
•
Frequency Response: 2 kHz
•
Voltage Span: 9 volt span for 12 bit A/D
•
Resolution: 2 mV/bit
•
Accuracy: 3% of full scale output
10.10.2 Vacuum probe
•
Range: 0-30 psia
•
Operating Temperature Range: -40 to
85°C
•
Voltage Span: 4.5 volts span for 12 bit A/D
•
Accuracy: 2% of full scale output
10.10.3 IR Temperature probe
•
Range: -18 to 260°C (0 to 500° F)
•
Accuracy:
±3%
whichever is greater
•
Response Time: 1 second
•
Emissivity: Fixed at 0.95
•
Operating Temperature Range: 0 to 65°C
•
Optical Resolution: 4:1 distance to target
ratio
•
10 MΩ input impedance
10.10.4 Low current probe
•
Range: 0-30 Amps
•
Operating Temperature Range: 0 to 70°C
•
Frequency Range: DC to 50 kHz (-3dB)
•
Output Sensitivity: 100 mV/Amp
•
Auto-zero adjustment
10.10.5 High current probe
•
Range: 0-1000 Amps
•
Operating Temperature Range: 0 to 70°C
•
Frequency Range: DC to 1 kHz (-3dB)
•
Output Sensitivity: 1 mV/Amp
•
Auto-zero adjustment
1 689 979 945 (28.07.2006)
of
reading
or
±3°,
11.
Software
11.1 Digital Volt Ohm Meter (DVOM)
•
DC Voltage
-
Voltage measurement ranges:
AutoRange
±400 mVolts - ±400 Volts
•
AC Voltage
•
Resistance
-
Resistance measurement ranges:
AutoRange
0-400 Ω − 0-40 MΩ
•
Continuity
•
Diode Check
11.2 4-channel oscilloscope
11.2.1 Trigger selection
•
Voltage Level Trigger selectable through
full voltage range
•
Position selectable from 0% to 100% of the
display
11.2.2 Trigger system
•
Normal – Only refreshes display if trigger
conditions are met.
•
Auto – Waveform is displayed if trigger
conditions are met or predetermined delay
time has elapsed.
•
Single
Shot
occurrence of signal that meets the trigger
selection.
•
Free Run – Generally used for slower time
base
(Defaults
selections of 2 seconds/div through 20
seconds/div)
11.2.3 Trigger edge
•
Rising/Falling edge selection
FSA 450
–
Captures
a
single
to
this
trigger
with
Robert Bosch GmbH