Visual inspection

General

During a visual inspection, the tests described below are to be carried out without further
dismantling of the equipment. Safety related parts must not show any visible defects. Fur-
thermore, defects which may present a danger during the visual inspection must be written
down.
Deficiencies identified that may be the cause of other hazards must be repaired immedi-
ately, otherwise further use must be restricted until the defect is rectified.
Mains Power Sup-
-
ply and Connec-
-
tion Cables
-
-
-
-
IMPORTANT! To determine the cross-section and current carrying capacity of mains ca-
bles, observe standard IEC 60364-5-52. As the current carrying capacity can vary due to
the cable layout and its insulation and differing ambient temperatures, when the mains
leads are replaced the requirements of standard IEC 60364-5-52 must be met. Individual
national requirements and standards must also be observed.
Housing and Cov-
-
ers
-
-
-
-
-
Adjustment and
-
display devices
Rating Plate and
-
Warning Stickers
-
Connection cables and external leads must not be damaged or defective.
Insulation must not be defective (do not use insulation or adhesive tape to repair dam-
age).
Plugs and plug connections must not be damaged or deformed.
Strain relief devices, bend radius protection devices, conduits and fixings must be ef-
fective.
Cables/plugs must be suitable for their area of application and power.
Fuse links and device fuse holders must not be defective.
Housing, insulation items and protective covers must not be missing or damaged.
Unauthorized modifications must not be present, e.g.: Fittings and modifications not
authorized by the manufacturer.
Ventilation openings must not be soiled or blocked, air filters must be present.
There must be no sign of soiling, corrosion or degradation that would compromise
safety.
Indications of overload and improper use must not be present.
Conductive objects must not be inside the housing.
Control elements and indicators must not be faulty
Safety-related labels must be present, e.g.: Warning notices, grounding symbols, and
rating plates. If necessary, renew, add to or correct the labels in a suitable form.
Ensure that all safety-related labels or symbols, rated values and position indicators
are legible.
53