Installation Instructions

Safety

A safety inspection must be carried out after the replacement, modification, maintenance
or repair of a component (see section "Safety Inspection").

ESD Guidelines

No guarantee or warranty claims can be made in respect of any improperly handled elec-
tronic component or PC board.
WARNING! An electric shock can be fatal. Before opening the device
-
Set power switch to - O -
-
Disconnect the device from the grid
-
Attach a clear warning sign advising others not to switch the power source
back on
-
Use a suitable measuring instrument to ensure that electrically charged com-
ponents (e.g., condensers) are discharged
WARNING! An electric shock can be fatal. Danger of residual voltage from ca-
pacitors. Wait until the capacitors have discharged. Discharge takes 6 minutes.
Additional information on discharge time can be found in the operating instruc-
tions and in the safety information on the inverter.
NOTE! Requirements for electrical installations may be subject to national stan-
dards and regulations, and these must be followed accordingly.
NOTE! Observe ESD guidelines when handling electronic components and PC
boards. This primarily applies to ESD-compatible
-
Packaging
-
Work surfaces
-
Floors
-
Seating
-
Grounding options
-
Handling