Herunterladen Inhalt Inhalt Diese Seite drucken

Noise Emission; Electromagnetic Compatibility (Emc); Technical Data - Würth MM 350 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
The noise emission measured in accordance with
EN 60974-1 at regular load and maximum operat-
ing point is less than 70 dB(A).
Electromagnetic compatibility
This appliance conforms to the current EMC
standards.
Please note:
Welding machines consume so much power
that they may affect public electricity networks.
For this reason the mains supply is subject to re-
quirements regarding the maximum permissible
network impedance. The maximum permissible
mains impedance (Z
mains grid (mains power supply) is specified
in the technical data. Contact the electricity
network operator if required.
The appliance is designed for welding both
in commercial and industrial environments
(CISPR 11 class A). Using the appliance in
another environment (e.g. in a residential area)
may affect electrical equipment in that area.
During start-up, electromagnetic problems may
be caused in:
• Power cables, control lines, signal and
telecommunication lines in the vicinity of the
welding / cutting appliance
• TV and radio stations / sets
• Computers and other control equipment
• Security equipment in commercial buildings
(e.g. alarm systems)
• Cardiac pacemakers and hearing aids
• Calibrating and measuring equipment
• Appliances with an insufficient interference
resistance
If any other facility or equipment in the surrounding
area is affected, additional protective barriers may
become necessary.
The surrounding area to be taken into considera-
tion may extend beyond the boundaries of the
premises. This depends both on the type of the
building and on the other activities performed
at the site.
Downloaded from
www.Manualslib.com

Noise emission

(EMC)
) of the interface to the
max
manuals search engine
Always observe information and instructions pro-
vided by the manufacturer when operating the
appliance. The company operating the appliance
is responsible for the setup and the operation of the
appliance. If electromagnetic disturbances occur, the
operating company is responsible for the elimina-
tion of this distubances (with technical help from the
manufacturer if necessary).

Technical data

Prod. no.
Welding range
No-load voltage
Voltage adjustment
Duty cycle 100 %, 40 °C
Duty cycle 20 %, 40 °C
Weldable wires, steel
Weldable wires, aluminium 1.0 - 1.6 mm Ø
Wirefeed rate
Mains voltage
Frequency
Mains fuse
Max. mains current con-
sumption
Max. capacity
Power factor
Cooling type
Class of insulation
Protection class (IEC 529)
Welding torch type
Dimensions (L x W x H)
Weight
Protection class
5952 352 350
25 - 350 A /
15.3 - 31.5 V
15.5 - 42.0 V
24 steps
160 A
350 A
0.6 - 1.6 mm Ø
1 - 23 m/min
400 V/3~
50/60 Hz
25 A tr/C
21.5 A
14.9 kVA
0.89 cos φ
F
F
IP 23
ML 3800
830 x 390 x 690 mm
104 kg
/ I
13