MA506
32
Trouble shooting
Message
FULL
Display flashing
Display flashing
Downloaded from
www.Manualslib.com
Switch on offset value change enable by simultaneously pressing the keys
+
.
For value modification use the arrow keys.
Press key
to take over and store the new value.
If no key has been pressed for approx. 20 s or if you press again key
the electronic display will return to display mode.
10 Trouble shooting
Error states are recognized and shown in the display:
Description
Display overrun
Missing referencing.
Faulty / no sensor sig-
nal.
11 Application Examples
Length measurement
Required: Display accuracy 1/10 mm. Display shall be zeroed via function key.
Designation
Resolution
Reference value
Offset
Decimal point
Counting direction
Time
Last value memory
Reset function enable
Increm. meas. function enable
Reference value change enable
Offset correction enable
Language
MA506 · Date 31.03.2017 · Art. No. 80713 · Mod. status 263/16
manuals search engine
Action
Check parameters and adjust them if neces-
sary; set display to reference value.
Set display to reference value.
Check sensor position.
Display
rES_
rEF_
oFF_
dP_
dIr_
P_SEC
rSto_
_F_AS
_F_rL
_F_rF
_F_oF
LAn_
English
,
Progr. value
0.1
0000.0
0000.0
0.0
UP
1 s
oFF
on
oFF
oFF
oFF
d