SIMUDRIVE SD100Hz
3.5
Safety edge wiring
DANGER
Wiring a safety edge is compulsory.
The operation must be carried out with the power off.
3.5.1
Connect the safety edge
Optical wired safety edge
> Illustration 8
Translation of the colours present on the safety edge wiring diagram:
EN
EN
Brown
Brown
Green
Green
White
White
Wired resistive safety edge 1.2 kΩ or 8.2 kΩ.
> Illustration 9
3.5.2
Adjust setting P2 according to the type of safety edge connected
1] Press the "SET" button for 0.5 s to enter parameter setting mode.
ð Indicator light P0 flashes once.
2] Press the "SET" button twice to move on to parameter P2.
ð Indicator light P2 flashes once to indicate the value selected.
3] Press the "+" or "-" button to change the value of the parameter.
ð The indicator light flashes x times to indicate the value selected.
• P2 = 1 x: Optical wired safety edge
• P2 = 2 x: Resistive wired safety edge 1.2 kΩ
• P2 = 3 x: Resistive wired safety edge 8.2 kΩ
4] Press the "SET" button for 2 s to confirm a value and exit parameter setting mode.
ð The parameter setting indicator lights go out.
3.6
Checking the motor direction of rotation
NOTICE
If the product has already been set in the factory, go directly to the remote control programming
stage.
> Illustration 10
1] Press and hold the "SET" button for 2 s.
ð The "POWER" indicator light flashes.
2] Press the "+" or "-" button to check the direction of rotation of the motor.
ð If the motor's direction of rotation is correct, move on to the Motor end stop setting [} p.32] step.
ð If the direction of rotation is incorrect, press the "+" and "-" buttons simultaneously until the motor
performs and up-down movement. The "POWER" indicator will light up continuously for 2 seconds.
ð Check the motor's direction of rotation again then move on to the Motor end stop setting
[} p.32] step.