Errortypes - HYDAC ELECTRONIC AquaSensor AS 3000 Bedienungsanleitung

Mit io-link schnittstelle
Vorschau ausblenden Andere Handbücher für AquaSensor AS 3000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AS 3000 IO-Link
octet
0
bit offset
31 - 24
subindex
1
element bit
7 - 0

ErrorTypes

Additional
Code
code
128 (0x80)
0 (0x00)
128 (0x80)
17 (0x11)
128 (0x80)
18 (0x12)
128 (0x80)
32 (0x20)
128 (0x80)
33 (0x21)
128 (0x80)
34 (0x22)
128 (0x80)
35 (0x23)
128 (0x80)
48 (0x30)
128 (0x80)
49 (0x31)
128 (0x80)
50 (0x32)
128 (0x80)
51 (0x33)
128 (0x80)
52 (0x34)
128 (0x80)
53 (0x35)
128 (0x80)
54 (0x36)
128 (0x80)
64 (0x40)
128 (0x80)
65 (0x41)
128 (0x80)
130 (0x82) Application not ready
129 (0x81)
16 (0x10)
129 (0x81)
17 (0x11)
129 (0x81)
18 (0x12)
Stand: 20.04.2020
1
2
23 - 16
15 - 8
2
3
7 - 0
15 - 8
Name
Device application error -
no details
Index not available
Subindex not available
Service temporarily not
available
Service temporarily not
available - local control
Service temporarily not
available - device control
Access denied
Parameter value out of
range
Parameter value above limit Written parameter value is above its specified value range
Parameter value below limit Written parameter value is below its specified value range
Parameter length overrun
Parameter length underrun
Function not available
Function temporarily
unavailable
Invalid parameter set
Inconsistent parameter set
Persistent memory error -
no details
Parameter could not be
saved
Parameter could not be
loaded
HYDAC ELECTRONIC GMBH
3
7 - 0
3
7 - 0
Description
Service has been refused by the device application and no
detailed information of the incident is available
Access occurs to a not existing index
Access occurs to a not existing subindex
Parameter is not accessible due to the current state of the
device application
Parameter is not accessible due to an ongoing local operation
at the device
Parameter is not accessible due to a remote triggered state of
the device application
Write access on a read-only parameter
Written parameter value is outside its permitted value range
Written parameter length is above its predefined length
Written parameter length is below its predefined length
Written command is not supported by the device application
Written command is not available due to the current state of
the device application
Written single parameter collides with other actual parameter
settings
Parameter inconsistencies were found at the end of block
parameter transfer, device plausibility check failed
Read or write service is refused due to a temporarily
unavailable application
Persistent memory access failed and no detailed information
of the incident is available
Parameter could not be saved to persistent memory
Parameter could not be loaded or restored from persistent
memory
43