have to be acquainted with these operating
instructions and must be informed about the
equipment's potential hazards. It is also imperati-
ve to observe the accident prevention regulations
in force in your area. The same applies for the
general rules of health and safety at work.
The manufacturer will not be liable for any chan-
ges made to the equipment nor for any damage
resulting from such changes. Even when the
equipment is used as prescribed it is still impossi-
ble to eliminate certain residual risk factors.
The following hazards may arise in connection
with the machine's construction and design:
•
Contact with the saw blade in the uncovered
saw zone.
•
Reaching into the running saw blade (cut
injuries).
•
Kick-back of workpieces and parts of work-
pieces.
•
Saw blade fracturing.
•
Catapulting of faulty carbide tips from the saw
blade.
•
Damage to hearing if essential ear-muffs are
not used.
•
Harmful emissions of wood dust when used
in closed rooms.
4. Technical data
AC motor ..................................220-240V ~ 50Hz
Power P ......................................S6 40% 2000 W
Idle speed n
........................................ 2950 rpm
0
Carbide saw blade .......... Ø 315 x Ø 30 x 2.8 mm
Number of teeth ............................................... 40
Table size ...................................... 800 x 550 mm
Table length extension .................. 740 x 400 mm
Cutting height max. ........................... 85 mm / 90°
........................................................ 55 mm / 45°
Height adjustment .................... infi nite 0 - 85 mm
Tilting saw blade .......................... infi nite 0° - 45°
Max. workpiece width ................................. 1.6 m
Extractor connection .......................Ø100/36 mm
Weight without slide ...................... approx. 52 kg
Weight with slide ........................... approx. 57 kg
Protection class: ................................................. I
Thickness of the splitter: ......................... 2.5 mm
Operating mode S6 40%: Continuous operation
with idling (cycle time 10 minutes). To ensure that
the motor does not become excessively hot, it
may only be operated for 40% of the cycle at the
Anl_TC_TS_315_U_SPK9-1.indb 30
Anl_TC_TS_315_U_SPK9-1.indb 30
GB
specifi ed rating and must then be allowed to idle
for 60% of the cycle.
Danger!
Sound and vibration
Sound and vibration values were measured in
accordance with EN 1870-19.
Operation
L
sound pressure level ..................... 95,1 dB(A)
pA
K
uncertainty ........................................ 3 dB(A)
pA
L
sound power level ..................... 109,1 dB(A)
WA
K
uncertainty ........................................ 3 dB(A)
WA
The quoted values are emission values and not
necessarily reliable workplace values. Although
there is a correlation between emission and im-
mission levels it is impossible to draw any certain
conclusions as to the need for additional precau-
tions. Factors with a potential infl uence on the ac-
tual immission level at the workplace include the
duration of impact, the type of room, and other
sources of noise etc., e.g. the number of machi-
nes and other neighboring operations. Reliable
workplace values may also vary from country to
country. With this information the user should at
least be able to make a better assessment of the
dangers and risks involved.
Wear ear-muff s.
The impact of noise can cause damage to hea-
ring.
Keep the noise emissions and vibrations to a
minimum.
•
Only use appliances which are in perfect wor-
king order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever ne-
cessary.
•
Switch the appliance off when it is not in use.
Caution!
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
- 30 -
23.03.2020 09:16:56
23.03.2020 09:16:56