Display
• •
• •
⊗ ⊗ ⊗
⊗ ⊗
/
⊗ ⊗
• • •
LED off
Note
The tester is not suitable for use on two-wire networks (protective multiple
earthing).
Reversing of neutral conductor and PE conductor (ground) will not be
detected by the tester!
Note
Check that the socket tester is operating correctly before use by testing on a
correctly wired socket!
*Note
RCD triggering only occurs with clockwise phase rotation.
Note
By pressing FI/RCD-Test (< 3 seconds) you can check your residual-current
device (30 mA / 230 V AC) for correct functionality.
12
Automatic test sequence
Description
L>
L<
PE
L
N
L<>PE
L<>PE&PE Live / PE reversed and PE open circuit
LED on
OK, clockwise phase rotation at the device
OK, anticlockwise phase rotation at the
device*
No PE (protective earth)
No live
No neutral, clockwise/anticlockwise phase
rotation at the device
Live / PE reversed